The Information Requirement of In-Place Push Recovery on Force-Sensorless Humanoids
1 Korea University · 2 University College London
Lateral hand pushes of about 40 N with steps enabled: with the hold layer off the robot steps, with it on the feet stay planted. Selected illustrative trials; the registered test is in Hardware.
Largest lateral push held per block, steps disabled, 12 blocks each (median; p = 5×10−6).
Behind a load cell, ours against a momentum observer, without force/torque sensors.
Pre-registered recovery criterion met, with 96 % less base displacement on holdable pushes.
Recovery steps can interrupt manipulation performed from a fixed stance, so a humanoid should recover within its existing foot contacts when they suffice and step only when they do not. But the centre of pressure can move only within the support region: a restoring response that comes late lets the push-driven motion grow until a new contact becomes necessary. Without force/torque sensors, the controller sees the push only through an estimate, and filtering that estimate trades noise for delay.
How late, and how wrong, may the push estimate be before a push that could be held ends in a step?
The project in 55 seconds, from the question to the hardware tests. Robot scenes are rendered in Viser on the MuJoCo G1 model.
We first fix the controller and feed its hold decision the true push force, delayed by L and corrupted by an error σ on purpose. What remains holdable is the requirement any estimate has to meet.
Near the boundary, ideal information held 10 of 12 pushes, a 10 ms delay still 10 and a 20 ms delay only 3. Actuation delay draws on the same budget as information delay. In this fixed-controller simulation, slow injected errors of 30 N were tolerated, whereas 20 N errors varying on the push’s time scale were not; neither registered monotonicity prediction held over the whole delay–noise grid, so noise size alone is not the requirement.
A linear inverted pendulum predicts the budget, e−ωΔL with ω = 3.79 s−1 on the G1. When the estimation error stays within tolerance, the hold-entry latency then predicts the normalised holdable force: three of four estimators matched this registered prediction in closed loop, with nothing fitted.
Try it
Each estimator reaches the hold decision after its own latency. Move the slider, or point at an estimator to see where it sits on the budget.
Simulation, final configuration, 380 runs. Squares: lateral, circles: fore-aft. Band: registered tolerance ±0.08. Three estimators matched the prediction within 0.017; the enhanced observer did not, fore-aft.
The measured requirement designs the rest: an estimate fast enough at low noise, and signal paths that filter each use of it differently.
A momentum observer differentiates a base velocity reconstructed from leg kinematics, which is noisy at low latency. This estimate measures the base acceleration with the pelvis IMU and solves the base and leg rows of the floating base model for the push wrench. It needs the torque of the 12 leg joints only. On the real G1 it followed a load cell by 29 ms, against 57 ms for a momentum observer.
The estimate reaches the hold layer by three paths. The decision path is unfiltered because latency comes first. The force bound takes a median to reject spikes. The feedforward keeps its filter. The stepping baseline stays underneath as the fallback.
The estimate from the pelvis IMU and the leg joints, the shared MPC structure with the hold layer, and the estimator swap on the same controller (simulation).
Simulation, 80 paired runs with pushes of 50 to 80 N. All rows share the plant, the stance controller and the pushes and differ only in the step decision and its information; the rule rows are step-triggering rules from the literature implemented on the same hold layer.
The registered criteria allowed at most 4 fewer recovered runs of the 80 and at most 80 % of the baseline’s steps (pass criteria, not a non-inferiority test). The cost savings concern motion and loading, not task performance.
The same 70 N lateral push on the stepping baseline and on ours: the baseline steps, ours keeps both feet in place. Kinematic reconstruction of the simulation run.
A real G1 in a safety gantry, pushed by hand through a load cell sampled at 7.5 kHz and logged on the robot’s clock.
The film at the top shows illustrative trials of the same controller with steps enabled and the hold layer off (stepping baseline) and on (ours), with load-cell force, hold mode and foot swing from the robot’s logs. The registered tests follow.
Registered test A1
Blocks of ours alternated with blocks of the same controller with only the hold entry disabled, 12 blocks each in two sessions. Each block was an ascending series of shoulder-height lateral pushes ended by a failure. The block score, the largest held push, had a median of 69 N with the hold layer and 0 N without it, which held no counted push in any block (one-sided Mann–Whitney over blocks, p = 5×10−6; each session alone 62 and 75 N against 0 N).
Per push the counts are descriptive, since the ablation met fewer high forces: between 40 and 80 N ours held 42 of 49 and the ablation 0 of 6. The ablation unloaded a foot in 23 of 24 pushes (22–56 N), consistent with the hold preserving contact; ours, keeping 10 % of the weight on each foot, failed at 52–84 N.
Holding in place. With our controller in command and steps disabled, 21 of 22 lateral pushes of 26–59 N were held without a step under a registered outcome rule. The hold mode started a median of 69 ms after the load-cell force crossed 25 N (interquartile range 59–144 ms). These no-delay trials support the holding result; the latency test they belonged to was stopped and gives no hardware delay result.
Estimators. 71 hand pushes with the estimators running in shadow, computed but not commanded. Real delay: median lag behind the load cell at 50 % of each signal’s own plateau.
| Estimator | Delay, real (ms) | Delay, sim (ms) | Push error (N) | Quiet noise (N) |
|---|---|---|---|---|
| Ours, IMU resolved | 29 | 15 | 8.4 | 2.7 |
| Centroidal estimate | 34 | 15 | 8.0 | 2.3 |
| Momentum observer | 57 | 45 | 11.0 | 2.2 |
| Enhanced observer | 63 | 50 | 8.6 | 2.4 |
In-place push recovery preserves a humanoid’s task stance. Without force/torque sensors, the controller must decide whether to hold using a delayed and noisy estimate, but how much delay and error it can tolerate is unclear. We measure this information requirement on a simulated Unitree G1 by feeding a fixed hold-or-step controller the true push force, delayed and corrupted. In boundary tests, the initial loss of holdable force agreed with the pendulum rate of about 3.7 % per 10 ms; actuation delay drew on the same budget, and slow errors of 30 N were tolerated while 20 N errors on the push’s time scale were not. The requirement guides an estimate that resolves the pelvis inertial measurement unit through the floating-base model, retains the joint accelerations and needs no upper-body torques; for three of four estimators, hold-entry latency predicted the normalised holdable force within 0.02 (registered tolerance 0.08). The resulting controller met its pre-registered recovery criterion against a stepping baseline with 49 % fewer steps and, on holdable pushes that both controllers recovered from, 96 % less base displacement. On the real G1, the estimate followed a load cell by 29 ms, against 57 ms for a momentum observer, and with steps disabled, the largest lateral push held per block had a median of 69 N with the hold layer, whereas without it no block held a push (12 blocks each). Disturbance estimates for balance should therefore be judged by the recovery they preserve.
The registered latency test was stopped because hand-push variability could not resolve the predicted 7–14 % effect, and recovery with stepping was not evaluated in a registered test; the film at the top of the page is illustrative. Under the robot’s own arm motion, the advantage over the centroidal estimate was not met at the registered bandwidth; in a registered follow-up with the filter tuned toward the momentum observer’s delay, ours read the least spurious force of the three (15.7 against 18.9 and 18.4 N). The cost comparison measured motion and loading, not task performance, and the rounded sole of the real robot may reduce the usable centre-of-pressure margin, an effect not quantified.
Every reported test was registered with a recorded hash before it ran.
The arXiv identifier will be added when the preprint is posted.
@misc{kim2026holdbeforeyoustep,
title = {Hold Before You Step: The Information Requirement of
In-Place Push Recovery on Force-Sensorless Humanoids},
author = {Kim, Jeonghyeon and Kim, Jaesang and Park, Shinsuk},
year = {2026},
note = {Preprint}
}